R-Value Performance of BuildBlock ICF System

The R-value of insulated concrete forms (ICF) is a measure of thermal resistance used in the building and construction industry. It is generally understood to indicate how efficient the insulation value of the material or product.

R-value under uniform conditions it is the ratio of the temperature difference across an insulator and the heat flux (heat transfer per unit area per unit time, QA) through it or R=ΔT/QA. Thermal resistance varies with temperature but it is common practice in construction to treat it as a constant value. (A common method is to standardize the temperature at which the values are reported. (75° typical) (1).

BuildBlock insulated concrete forms consist of two panels of Expanded Polystyrene (EPS), a light-weight closed cell material. Each panel is 2.5” thick. Common Type II EPS R-values range from 3.9 – 4.4  (1,2). The R-Value of BuildBlock forms is R-23,4.2/inch, across 5 inches of foam depth.

There are additional factors that help to push the Performance R-value to R-30 – R-50. This performance will reduce the needed size of the HVAC units, and will keep the home at a more constant comfort level.

R-Value of BuildBlock Insulated Concrete Form Products

 

Material
R-Value

Performance
R-Value

BuildBlock R-23 R-45-55
BuildLock KD R-23 R-45-55
BuildDeck 8” R-23 R-48-58
BuildDeck 10” R-29 R-50-60
BuildDeck 12” R-36 R-55-65
BuildDeck 12”+2” R-42 R-65+
ThermalSert 1” +4.2
ThermalSert 2” +8.4
ThermalSert 4” +16.8

NOTE: Calculate R-values using 4.2 R’s per inch based on 1.5 lb/ft3 density. Performance R-values may vary by climate zone, solar orientation, performance R-values plateau once insulation thickness approaches 10- inches.

Performance Over Time

EPS insulation does not degrade over the normal lifespan of a building and in tests performed by the Expanded Polystyrene Industry Alliance (EPS-IA), it is demonstrated that over extended periods of time, even in direct contact with the soil, EPS will retain most of its stated R-value.

Furthermore, EPS exhibits cyclical drying, allowing moisture which is absorbed into the foam, to also dry out from the foam. The report states that Type II EPS (the material used in BuildBlock ICF products) can exhibit a significant drying potential, which “is critical to maintaining thermal resistance (R-value) under severe long term exposure conditions.” (3) All building materials exposed to moisture, weather, humidity, etc. will both gain and lose moisture, depending on current conditions. The difference with EPS foam is that it doesn’t affect the insulation value. Simply put, EPS foam is like wool socks for your home, even when damp, they still keep you warm.

EPS foam will maintain its R-value, even with significant saturation percentages. In contrast, Extruded Polystyrene (XPS) foam, has lower moisture absorption rates and is more dramatically affected by small amounts of moisture. XPS below grade systems can experience a 10‐44% loss of energy savings performance when subjected to moisture accumulation in the range of 8% ‐ 16%. (EPS-IA Technical Bulletin, referencing a study at Oak Ridge National Laboratories (ORNL) in 2012). (4,5)

How Design & Location Effect R-Value

Performance values of insulated concrete forms vary by temperature, location, number of openings and orientation of the house. Many ICF homes will perform in the range of R-30 – R-50. Here are some factors to consider when designing a home:

  • ICFs will perform better in colder temperatures, because EPS exhibits higher R-values at lower temperatures.
  • Properly placed or more efficient windows will contribute to a higher performance value.
  • Orientation of the home is important in order to take advantage of passive solar gain in the winter while minimizing it in the summer.
  • Design large eaves into a home to help shield the sun when it’s more directly overhead, and allow it to warm the home through large areas of glass when it is lower on the horizon.
  • Direct prevailing winds around the home with usage of trees or landscaping.
  • By using fewer and smaller windows on the north walls, the wind will have less of an effect on the indoor temperatures.
  • ICF, being a poured monolithic wall, virtually eliminates air infiltration, which causes drafts and cold spots. Keeping the whole home more comfortable is the goal of any insulation system.

By controlling and eliminating conductive losses, insulated concrete form home construction can provide the highest levels of comfort in any weather.

SOURCES:

  1. Wikipedia, R-value Insulation, http://en.wikipedia.org/wiki/R-value_(insulation)
  2. Inspectapedia, Table of Insulation Material R-Values & Other Materials’ Insulating Properties, http://inspectapedia.com/interiors/ Insulation-Values-Table.htm#Styrene
  3. EPS-IA, EPS Below Grade Series 104, February 2014, Drying Potential of Polystyrene Insulations Under Extreme Environmental Cycling Conditions
  4. EPS-IA, EPS Below Grade Series 105, March 2014, XPS Insulation Extracted After Field Exposure Confirms High Water Absorption & Diminished R‐Value (referencing a study at Oak Ridge National Laboratories (ORNL) in 2012)
  5. Oak Ridge National Laboratory, Measurement of Exterior Foundation Insulation to Assess Durability in Energy-Saving Performance, April 2012, Manfred Kehrer, Jeff Christian.
  6. Autodesk Sustainability Workshop, R-Values and Insulation. http://sustainabilityworkshop.autodesk.com/buildings/insulation